Table 54b Formula



  1. Volume Correction Factor Table 54b Formula
  2. Astm Table 54b Formula

Volume correction factors — diesel fuel Density at 15 °C = 840 kg/m3 (table 54B) Refer to bulletin V-18 for more information on product classes. Volume correction factors to 15 °C for use with all grades of diesel, bio-diesel and diesel blends (including B100). Table 54B= Table 54D= User info General formula: VCF=exp(b) and: a=(K0+K1xDensity @ 15/vac)/(Density @ 15/vac^2) diff temp= b=-a x diff temp x (1+0,8 x a x diff temp) diff temp=actual temp-15 Formula for Table 54B and 770.

BUNKER CALCULATION
It has been observed that even for such a simple procedure much headache is being taken.
The bunker calculation is simple and needs the following:
– Tank Sounding data and Tank Capacity Table. The Corrected Sounding means below is the sounding after correcting with vessel’s trim and list.
– Temperature of Oil on Tanks,
– Oil Density @15C,
– Table ASTM 54B (VCF) and Table ASTM 56 (WCF
Commonly this is done prior to and after a time charter period than mentions as On Hire Bunker (prior) and Off Hire Bunker (after), the Bunker Survey is required to check the amount Bunker transferred or supplied onto the Ship’s Tanks. This job is associated with Ship’s Chief Engineer, the Person who responsible for bunker onboard.
Now we could go with sample of 1 tank to test the calculation.
** Question :
FO Tank No. 1 Center, Corrected Sounding = 3.27 Meter, Temperature = 34 degrees celcius, Density @ 15 C = 0.9870.
Tank Volume at Sounding 3.20 M = 157.20 Cubic Meter, at Sounding 3.30 M = 163.60 Cubic Meter.
** Answer :
– The Quantity in Metric Ton = Oil Vol x VCF x WCF,
– Observe Volume = {(3.27 – 3.20) / (3.30 – 3.05) x (163.60 – 157.20)} + 157.20 = (0.07/0.10) x (6.40) + 157.20 = 4.48 + 157.20 = 161.68 Cu.M.
– T 54B (VCF) > Density @ 15C 0.9903 at 34 C = 0.9870 (see the picture below you need to interpolate if any different numbers on both columns).
T 56 (WCF) : Density @15C 0.9903 at 34 C = 0.9892 (Quick formula with reducing factor for WCF is Density @ 15C – 0.0011 = 0.9903 – 0.0011 = 0.9892). We don’t need to see the table anymore.
– So, The Quantity in MT is 161.68 x 0.9870 x 0.9892 = 157.85 MT. Sample calculation tanks sounding attached below.
If you do calculation with Volume in Barrel, just uses ASTM Table 6B for VCF, ASTM Table 11
for WCF in Long Ton and then ASTM Table 13 for WCF in Metric Ton.

5 671

ASTM / API TABLES
TABLE 54A (Crude Oil).
TABLE 54B (Products).
TABLE 6A (Crude Oil).
TABLE 6B (Products).
Temperature Deg. F to Deg. C.
Temperature deg. C to Deg. F.
Weighted Average temperature calculated.
DRY DENSITY CALCULATION.
PARTIAL WET DENSITY CALCULATION.
ASTM 6 A - Tafel or Routine.
ASTM 6 B - Tafel or Routine.

Super ASTM ver. 4.0
DENS Vac @ 15°C
DENS Air @ 15°C
SP. GRAV @ 60°F
T11 - (LT/Bbls)
T13 - (MT/Bbls)
T52 - (M3/Bbls)
QTY TO LOAD (MT Air @ 15°C)
MT Air @ 15°C
M3 @TEMP
M3 @ 15°C
BBLS @ TEMP
BBLS @ 60°F

Calculation ASTM table of crude oil и oil products 5A, 6A, 5B, 6B, 6C, 23A, 24A, 23B, 24B, 24C, 53A, 54A, 53B, 54B, 54C.

DOWNLOAD here => ASTM-TABLES-FOLDER

Table 54b excel formula54b54bTable 54b excel formula

Volume Correction Factor Table 54b Formula

Table

Astm Table 54b Formula